Texas Instruments /MSP432P401M /REF_A /REFCTL0

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as REFCTL0

15 1211 87 43 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (REFON_0)REFON 0 (REFOUT_0)REFOUT 0 (REFTCOFF_0)REFTCOFF 0 (REFVSEL_0)REFVSEL 0 (REFGENOT_0)REFGENOT 0 (REFBGOT_0)REFBGOT 0 (REFGENACT_0)REFGENACT 0 (REFBGACT_0)REFBGACT 0 (REFGENBUSY_0)REFGENBUSY 0 (BGMODE_0)BGMODE 0 (REFGENRDY_0)REFGENRDY 0 (REFBGRDY_0)REFBGRDY

REFTCOFF=REFTCOFF_0, REFGENRDY=REFGENRDY_0, REFGENACT=REFGENACT_0, REFOUT=REFOUT_0, REFON=REFON_0, REFBGACT=REFBGACT_0, REFGENBUSY=REFGENBUSY_0, REFBGOT=REFBGOT_0, BGMODE=BGMODE_0, REFBGRDY=REFBGRDY_0, REFGENOT=REFGENOT_0, REFVSEL=REFVSEL_0

Description

REF Control Register 0

Fields

REFON

Reference enable

0 (REFON_0): Disables reference if no other reference requests are pending

1 (REFON_1): Enables reference in static mode

REFOUT

Reference output buffer

0 (REFOUT_0): Reference output not available externally

1 (REFOUT_1): Reference output available externally. If ADC14REFBURST = 0, output is available continuously. If ADC14REFBURST = 1, output is available only during an ADC14 conversion.

REFTCOFF

Temperature sensor disabled

0 (REFTCOFF_0): Temperature sensor enabled

1 (REFTCOFF_1): Temperature sensor disabled to save power

REFVSEL

Reference voltage level select

0 (REFVSEL_0): 1.2 V available when reference requested or REFON = 1

1 (REFVSEL_1): 1.45 V available when reference requested or REFON = 1

3 (REFVSEL_3): 2.5 V available when reference requested or REFON = 1

REFGENOT

Reference generator one-time trigger

0 (REFGENOT_0): No trigger

1 (REFGENOT_1): Generation of the reference voltage is started by writing 1 or by a hardware trigger

REFBGOT

Bandgap and bandgap buffer one-time trigger

0 (REFBGOT_0): No trigger

1 (REFBGOT_1): Generation of the bandgap voltage is started by writing 1 or by a hardware trigger

REFGENACT

Reference generator active

0 (REFGENACT_0): Reference generator not active

1 (REFGENACT_1): Reference generator active

REFBGACT

Reference bandgap active

0 (REFBGACT_0): Reference bandgap buffer not active

1 (REFBGACT_1): Reference bandgap buffer active

REFGENBUSY

Reference generator busy

0 (REFGENBUSY_0): Reference generator not busy

1 (REFGENBUSY_1): Reference generator busy

BGMODE

Bandgap mode

0 (BGMODE_0): Static mode

1 (BGMODE_1): Sampled mode

REFGENRDY

Variable reference voltage ready status

0 (REFGENRDY_0): Reference voltage output is not ready to be used

1 (REFGENRDY_1): Reference voltage output is ready to be used

REFBGRDY

Buffered bandgap voltage ready status

0 (REFBGRDY_0): Buffered bandgap voltage is not ready to be used

1 (REFBGRDY_1): Buffered bandgap voltage is ready to be used